ATLAS SCT Digitization: Time Scanning

2010.11.26 Taka Kondo (KEK) 

Toy MC results: plots and root files as of 2010.11.26

  • Setting parameters and result plots are written in ClockTimingScan_2_v4.ppt.

    CASE model pulse shape mean cluster size tot and missed fraction
    standard no crosstalk edge-sensing standard
    A SCT-DM old tscan_A.png
    tscan_A.root
    tscan_A_no.png
    tscan_A_no.root
    tscan_A_edge.png
    tscan_A_edge.root
    tot_A.png , missF_A.png
    missF_A.root, missF_A_25.root
    B SCT-DM new tscan_B.png
    tscan_B.root
    tscan_B_no.png
    tscan_B_no.root
    tscan_B_edge.png
    tscan_B_edge.root
    tot_B.png , missF_B.png
    missF_B.root, missF_B_25.root
    C ICM old tscan_C.png
    tscan_C.root
    tscan_C_no.png
    tscan_C_no.root
    tscan_C_edge.png
    tscan_C_edge.root
    tot_C.png , missF_C.png
    missF_C.root, missF_C_25.root
    D ICM new tscan_D.png
    tscan_D.root
    tscan_D_no.png
    tscan_D_no.root
    tscan_D_edge.png
    tscan_D_edge.root
    tot_D.png , missF_D.png
    missF_D.root, missF_D_25.root
    plotting macro plot_tscan.C plot_tot.C ,plot_missF.C
    toy MC program
    in Athena
    ySCTtscan_v1.h ySCTtscan_v1.cxx
    ySCTtscan_v1.py GetExEy_150V.cxx
    GetPotential.cxx
    ySCTtscan_v3.h ySCTtscan_v3.cxx
    ySCTtscan_v3.py GetExEy_150V.cxx
    GetPotential.cxx


    other related links:
  • eh_transport page
  • pulse_shape page
  • phi_distribution page
  • mapping page
  • depletion voltage and leak current prediction